Brand: Schneider Electric. Series: ATV Mfr. Part No.: ATV71HU75N4. Description: Schneider Electric kW ATV71 Series 3 Phase Inverter; IP20;. Schneider Electric ATV71HU75N4 Motor Drives are available at Mouser Electronics. Mouser offers inventory, pricing, & datasheets for Schneider Electric . ATV71HU75N4 Schneider Electric Motor Drives /VAC ALTIVAR 71 DRIVE datasheet, inventory, & pricing.

Author: Zolomi Taukora
Country: Sudan
Language: English (Spanish)
Genre: Business
Published (Last): 25 September 2015
Pages: 66
PDF File Size: 19.25 Mb
ePub File Size: 14.92 Mb
ISBN: 679-4-89632-250-8
Downloads: 12370
Price: Free* [*Free Regsitration Required]
Uploader: Taujas

The cable shielding must be earthed.

The logic output can be used to signal that the machine is in a safe stop state. Drive against exceeding limit speed Drive against input phase loss Drive break on the control circuit Drive input phase breaks Drive line supply overvoltage Drive line supply undervoltage Drive overcurrent between output phases and earth Drive overheating protection Drive overvoltages on the DC bus Drive short-circuit between motor phases Drive thermal protection Motor motor phase break Motor power removal Motor thermal protection.

Add to My Documents. Altivar 71 product or component type Variable speed drive product specific application Complex, high-power machines component name ATV71 motor power kW 7. Use special filters with IP 54 protection.

ATV71 Quick Start annex: Specific Recommendations for Mounting the Drive in an Enclosure. For atv71hu775n4 times requiring more than 30 seconds in category 1, use a Preventa XPS AV safety module which can provide a maximum atv71hu75j4 delay of seconds. Connection of the common for the logic inputs depends on the positioning of the SW1 switch.

In this case the time delay must be adjusted on the drive controlling the motor that requires the longest stopping time.

ATV71HU75N4 – variable speed drive ATV71 – kWHP – V – EMC filter-graphi

X Switching frequency 1 Mounting type. Used for remote signalling of the drive status. SCCR and branch circuit protection pdf. Configurable relay logic 3 mA at 24 V DC. Use special filters with IP 54 protection. Fit interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. LI5 positive logic source11 V state 0 LI Used for remote signalling of the drive status. The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions: Configurable relay logic 3 mA at 24 V DC.

Related Posts (10)  1N4746A PDF

AO1 software-configurable current Ensure that there is sufficient ventilation. These contacts are independent aatv71hu75n4 each drive.

AO1 software-configurable current If there is not, install a forced ventilation unit with a filter. ATV71 Guide de programmation pdf. ESC can be used to set external starting conditions.

Access Denied

The logic output can be used to signal that the machine is in a safe state. Vector control without speed feedback. Avoid placing it close to heating elements. Internal supply for reference potentiometer 1 to 10 kOhm The derating curves for the drive nominal current In depend on the temperature, the switching frequency and the mounting type. ATV71 Guida alla programmazione pdf. Connection of the common for the logic inputs depends on the positioning of the SW1 switch. Ensure that there is sufficient ventilation.

Characteristics Main range of product Altivar The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions: ATV71 Installationsanleitung 0,37 – 90 kW pdf. SCCR and branch circuit protection pdf. Drive against exceeding limit speed Drive against input phase loss Drive break on the control circuit Drive input phase breaks Drive line supply overvoltage Drive line supply undervoltage Drive overcurrent between output phases and earth Drive overheating protection Drive overvoltages on the DC bus Drive short-circuit between motor phases Drive thermal protection Motor motor phase break Motor power removal Motor thermal protection.

Related Posts (10)  AS PALAVRAS VOAM CECILIA MEIRELES PDF

Range web site Solutions. LI5 positive logic source11 V state 0 LI For stopping times requiring more than 30 seconds in category 1, use a Preventa XPS AV safety module which can provide a maximum time delay of seconds.

Altivar 71 product or component type Variable speed drive product specific application Complex, high-power machines component name ATV71 motor power kW 7. Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories.

In this case the time delay must be adjusted on the drive controlling the motor that requires the longest stopping time.

The protective blanking cover may vary according to the drive model refer to the user guide. Depending on the conditions in which the drive is atv71hu754n be used, its installation will require certain precautions and the use of appropriate accessories. Add to My Documents. LI6, PWR terminal 2. Specific Recommendations for Mounting the Drive in an Enclosure.

Fit interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. The logic output can be used to signal that the machine is in a safe stop state. By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP Asynchronous motors Synchronous motors.

Logic inputs LI1 and LI2 must be assigned to the direction of rotation: